Guangzhou OSUNSHINE Environmental Technology Co., Ltd 86-020-38246006  info@ozocenter.com
1 KG 2KG 5KG Commercial Oxygen Generator For Water Treatment Project

1 KG 2KG 5KG Commercial Oxygen Generator For Water Treatment Project

  • লক্ষণীয় করা

    longevity ozone generators

    ,

    high concentration ozone generator

  • Ozone output
    1 Kg/h
  • material
    ozone enamel tube
  • application
    water treatment
  • MOQ
    1 set
  • Warrany
    12 months
  • Cooling Water Flow way
    1.2-1.5 M3/HKGO3
  • Ozone Concentration
    80-100MG/L
  • Place of Origin
    Guangdong China
  • পরিচিতিমুলক নাম
    Netech
  • Model Number
    NT-DGY 1.0
  • Minimum Order Quantity
    1 set
  • মূল্য
    for futher discussion
  • Packaging Details
    Safe double carton package with foam inside for protection
  • Delivery Time
    40 days after payment confirmed
  • Payment Terms
    EXW / FOB / CIF
  • Supply Ability
    1000 sets per month

1 KG 2KG 5KG Commercial Oxygen Generator For Water Treatment Project

1 KG 2KG 5KG Large Ozone Generator For Water Treatment Project

 

 

1.Applications

Ozone be used in chemical, petroleum, papermaking, textile, pharmaceutical, fine chemical and flavors and fragrances industry as the oxidant, catalyst. Its super-oxidation capacity and easy to cut off the associative key of Alkenes, Alkynes, and Benzene organics, increase the process oxidation, synthesis of new compounds. Because the high-speed, high efficiency, low energy consumption, ozone being more and more popular for industrial and scientific research.

Recently years, ozone is widely used in drinking water treatment, industrial sewage water treatment as it has the ability of high kill rate of bacteria, viruses and other microorganisms with high speed, and complete removing the organic compounds and other pollutants without creating secondary pollution, also can reduce the biological oxygen demand (BOD) and chemical oxygen demand (COD), remove nitrite, suspended solids and decolorization in water.

 

2Technical Description

1. Use enamel tubes for the core parts of ozone generator. The anti-force capability of resistant electricity is much better than glass and ceramic tubes.

2. In order to ensure the safety and continuously operating of ozone discharge, each discharge cell is equipped with separated safety appliance. Single discharge unit failure does not affect the normal operation of other units.

 

3. Discharge chamber

1. Use stainless steel for the case, resistant to rust & corrosion, and can effectively prevent the cooling water fouling.

 

4. High frequency of power supply

1. Precise setting the Voltage and Working frequency. Output frequency resolution can be up to ± 0.1Ht. Voltage Precision ±1V.

2. Has a perfect overload, automatic current-limiting, overpressure, short circuit, lack of phase and power-off protection.

3. SPWM modulation technology. Power factor COSθ can be 0.9.

 

5. High voltage transformer

1. Using Mn-Zn ferrites for magnetic core. Small wastage of iron core / low Resistivity / low temperature coefficient / high rate of dynamic permeability under high frequency working condition.

2. Using special cables of high frequency & stranded conductor to reduce the skin effect of high-frequency current.

 

NT-DGY 1.0  1KG Ozone System Technical Parameters:

 

Item

NT-DGY1.0  Ozone Generator

Ozone Output

1,078 G/Hr

Ozone Concentration

80-100MG/L

Power Supply Voltage

380  3PH  50HZ

Power

8-10KW/HKGO3

Operating Voltage

3800V-4200V

Working Frequency

800 Hz

Oxygen Feed Flow Rate

8-10NM3/HKGO3

Air Source Dew Point

≤-45℃

Working Pressure of Discharge chamber

0.05-0.1Mpa

Outlet Air Temperature

≤30℃

Inlet Cooling Water Temperature

≤20℃

Cooling Water Temperature Rise

4-6℃

Cooling Water Flow

1.2-1.5 M3/HKGO3

 

 

Remark:Different working condition there will be10%-20% different of ozone capacity.

 

1 KG 2KG 5KG Commercial Oxygen Generator For Water Treatment Project 0

1 KG 2KG 5KG Commercial Oxygen Generator For Water Treatment Project 1